Grid Simulators for Every Inverter, Charger and Storage System

Any Grid. Any Fault. On Command.

Regenerative grid simulators for solar inverter makers, EV charger developers, battery storage integrators and test labs. Play back dips, frequency steps, harmonics and loss of grid on command, and send the power your device exports back to the building supply.

A grid simulator of four light grey steel cabinets with a small touchscreen showing waveforms and a red emergency stop, its black and orange power cables running along a floor tray to a solar inverter on a grey test panel.

What a grid simulator does

A grid simulator is a programmable AC power source that stands in for the utility grid. The device under test connects to it as it would to the grid, and the simulator holds the voltage and frequency steady or changes them on command.

That lets a lab run, on demand and repeatably, the faults and disturbances that grid-connected equipment has to survive in service. A regenerative unit also takes back the power the device exports.

The front of a grey steel cabinet: a touchscreen showing three sine waves in red, green and blue, a red emergency stop on a yellow backing, three indicator lamps and a key switch.
The front panel: waveform display, emergency stop, status lamps and key switch.

What it imitates

Voltage
The level on each phase, held steady, stepped, dipped, raised or cut to nothing for a moment.
Frequency
Stepped or ramped away from 50 or 60 Hz at a rate you set, to test how a device follows it.
Phase angle
A sudden jump in the angle of the waveform, as the grid sees after a switching event.
Waveform shape
Harmonics and interharmonics added to the sine wave to imitate a distorted supply.
Unbalance
One phase set apart from the other two, the way a real three-phase supply drifts out of balance.

Grid simulator types

Two questions sort most units: whether it can take power back from the device, and how many phases it supplies. Power rating, form factor and how far it scales come next.

A waist-high grey steel cabinet on casters with a touchscreen and red emergency stop on its sloped top, its cable running to a microinverter on a wooden test bench.
A single-phase unit on casters, wired to a microinverter on the bench.
TypeWhat it isWhere it fitsAsk first
RegenerativeWorks in all four quadrants: it supplies power to the device under test and also takes back the power the device exports, feeding it to the building supply instead of turning it into heat.Where it fits: Solar and storage inverters, bidirectional EV chargers and anything else that pushes power into the grid.Ask first: What share of returned power reaches the building supply, and what the unit does if the building supply has a fault.
Non-regenerativeSupplies power but has no path to return it. When the device under test exports power, a load bank wired in parallel has to absorb it.Where it fits: Devices that only draw power: appliances, power supplies, chargers that never export.Ask first: How the export from your device will be absorbed, and how much heat and cooling that adds to the room.
Single-phase and split-phaseOne output, or two outputs in opposite phase for split-phase systems. Some three-phase units switch to single-phase and keep their full rating.Where it fits: Microinverters, residential inverters, home EV chargers and single-phase appliances.Ask first: Whether the full rated power is still available in single-phase mode.
Three-phaseThree outputs that can be set together or one at a time, so unbalance and single-phase faults can be imitated.Where it fits: Commercial and utility inverters, DC fast chargers, storage power conversion systems, motor drives.Ask first: The voltage range per phase and line to line, and whether each phase can be programmed on its own.
Paralleled systemsUnits of the same rating linked under one master controller to reach a higher total power. One maker allows four units in parallel.Where it fits: Labs that start with one unit and add power later, and large inverters or chargers.Ask first: How many units can run in parallel, and whether single-phase mode still works when they do.
Cabinet or chassisHigher-power systems stand on the floor as a row of steel cabinets. One maker now fits a 60 kVA unit into a chassis that mounts in a test rack or on a bench.Where it fits: Cabinets for dedicated test bays; rack chassis where floor space is short or the unit moves between benches.Ask first: Weight, footprint, cooling air path and access needed at the front and back.

Grid events a simulator plays back

Each plot shows three-phase voltage before, during and after one event. The grey band is the event, and the dashed lines mark normal peak voltage.

These are drawings, not to scale. The depth, duration and rate for a real test come from the standard you test to, and the simulator's programmed sequence follows them step by step.

Phase 1Phase 2Phase 3

Voltage dip (sag)

A fault somewhere on the network pulls the voltage down for a fraction of a second or longer.

What it checks: Low voltage ride-through: the inverter keeps running for the time the standard sets, and may have to feed reactive power that matches the depth of the dip.

Voltage swell

Voltage rises above normal, for example when a large load drops off or a fault clears.

What it checks: High voltage ride-through, and overvoltage trip settings and their timing.

Short interruption

The supply disappears briefly, as when a breaker opens and recloses.

What it checks: Whether the device rides through, restarts cleanly or trips. Equipment immunity tests define these on the mains side.

Frequency step or ramp

Grid frequency moves away from 50 or 60 Hz when generation and demand fall out of balance.

What it checks: Low and high frequency ride-through, and frequency-watt response, where output power changes with frequency.

Phase angle jump

The waveform jumps forward or back in time when the network is switched or a fault occurs.

What it checks: That the inverter stays synchronized and does not trip or produce a current spike.

Harmonic distortion

A supply bent out of a clean sine wave by other loads on the network.

What it checks: How the device behaves on a distorted supply, how distorted its own output current becomes, and harmonic immunity.

Unbalance

One phase sits lower than the other two, common on networks with uneven loads.

What it checks: Three-phase devices under uneven phase voltages, and their protection against them.

Loss of grid (islanding)

The grid supply is cut while the inverter and a local load are still connected, so the inverter could keep a section of network live on its own.

What it checks: Anti-islanding: the inverter must detect the lost grid and stop exporting within the time the standard allows.

Standards grid simulators are used for

Which of these apply depends on the product and the market it is sold into. The descriptions summarize the issuing bodies' own pages; the standards themselves are sold by those bodies, so check the current edition before you plan a test.

StandardWhat it coversWhere a grid simulator comes in
IEEE 1547-2018Interconnection and interoperability of distributed energy resources with electric power systemsSets the performance requirements for equipment that connects to the grid, including response to abnormal voltage and frequency, power quality and islanding. Written for 60 Hz systems.
IEEE 1547.1-2020Conformance test procedures for equipment interconnecting distributed energy resourcesThe test procedures that show equipment meets IEEE 1547. A grid simulator supplies the abnormal voltages and frequencies the tests call for.
UL 1741, Supplement SBThird edition supplement for grid support utility interactive invertersCalifornia's equipment lists ask for UL 1741 third edition with Supplement SB. Its tests include anti-islanding, voltage and frequency ride-through, volt-var, volt-watt and frequency-watt.
IEC 62116:2014Utility-interconnected photovoltaic inverters: test procedure of islanding prevention measuresThe test procedure for anti-islanding on single and multi-phase PV inverters. Its test equipment list includes an AC power source and AC loads.
IEC 61000-4-11Voltage dips, short interruptions and voltage variations immunity tests, input current up to 16 A per phaseImmunity of equipment on 50 or 60 Hz low-voltage supplies. One maker's software also has presets for parts 4-13, 4-14 and 4-28 of the same series, and its test list names part 4-34.
UL 9741Bidirectional electric vehicle (EV) charging system equipmentCovers chargers that charge a vehicle from the grid and can also export power from the vehicle back to it, the vehicle-to-grid case.

Who uses grid simulators

Companies and labs that build, certify or study equipment that connects to the grid. The setup is much the same: the grid simulator on the AC side, the device under test in the middle, and whatever feeds the device on the other side.

A white string inverter on a grey test panel, a red and black DC cable from a power supply and an AC cable to a row of grey grid simulator cabinets beside it, a technician checking the AC cable with a clamp meter.
An inverter on a test panel: DC in from the left, AC out to the grid simulator cabinets on the right.

Solar and storage inverters

Inverter makers use a grid simulator to run ride-through, frequency response and anti-islanding tests before sending units to a certification lab, and labs use the same setup to certify them. A DC source or PV simulator feeds the inverter, and the grid simulator stands in for the utility on the AC side.

A tall white DC fast charger in a lab bay with its cable plugged into a grey test load, its input cable crossing a floor cable protector to grey grid simulator cabinets.
A DC fast charger under test, its input supplied by the grid simulator at the side of the bay.

EV chargers, including bidirectional

AC and DC chargers draw power from the grid simulator while it applies dips, interruptions and distortion. Bidirectional chargers also push power back, so the simulator has to take it, which is where regeneration matters.

Two battery racks and a power conversion cabinet inside a yellow floor marking, linked by an overhead cable tray to a row of four grey grid simulator cabinets.
Battery racks and a power conversion system wired overhead to a four-cabinet grid simulator.

Battery storage and microgrids

A storage power conversion system charges and discharges, so the simulator has to source power one moment and absorb it the next while holding grid voltage steady. Microgrid controllers are tested against the distorted voltage and frequency they will see off grid.

Two researchers seen from behind at a monitor showing waveforms, beside a rack of real-time simulator chassis and a row of grey grid simulator cabinets.
Real-time simulator chassis on the desk, the grid simulator cabinets along the wall.

Power hardware-in-the-loop research

In power hardware-in-the-loop work, a real-time simulator models the grid and the grid simulator acts as the power amplifier, reproducing the modeled voltage at the terminals of real hardware. That needs an analog input and a short delay from signal to output.

Other uses

Appliances and power supplies
Immunity tests to voltage dips, interruptions and variations, and limit tests for the harmonic current a product draws.
On-board chargers
Vehicle chargers tested on the AC side across the voltages and disturbances they will meet.
Wind converters
Converters for wind turbines are also tested against a simulated grid, at higher power than most inverters.

How to choose a grid simulator

Start from the device you test and the standard you test it to. These are the points that separate one unit from another once the power rating is settled.

Power rating
Size to the device's rated output with margin, and count apparent power (kVA), not only real power (kW), because ride-through tests can call for reactive power.
Phases and voltage
Single-phase, split-phase or three-phase, and the highest voltage you must reach, including swell and overvoltage test levels above nominal.
Frequency range
Both 50 and 60 Hz if you sell into both markets, plus the steps and ramps your frequency tests need.
Regenerative or not
If the device exports power, a regenerative unit takes it back. Otherwise plan a load bank for the export and the cooling it needs.
Transient response
How fast voltage and frequency can change. Ask for the slew rate and whether you can set it, since some tests want a defined ramp.
Waveform control
How many harmonic orders it can add, whether it can add interharmonics, and how many steps a programmed sequence can hold.
Test software
Ready-made sequences for the standards you test to save setup time. Check which editions they follow.
Interfaces
LAN and USB are common; ask about GPIB, CAN and drivers for your automation software, and about an analog input for hardware-in-the-loop.

Installing one in your lab

Building supply
The unit draws from your building supply and, if regenerative, returns power to it. Get the input voltage, current and breaker size from the supplier early.
Isolation
Ask whether the output is isolated from the input. One maker builds isolation into the input side so no separate isolation device is needed on the device side; others may need a transformer.
Protection
One maker's units raise an alarm and stop when they see overvoltage, undervoltage, abnormal frequency, phase imbalance or overcurrent at the grid connection. Ask what yours does and how it restarts.
Cooling and space
Cabinets need clearance for air and for front and rear access. A non-regenerative setup adds the heat from the load bank.
Cabling
Output cables, the device under test and any disconnect switch should be planned with the electrician who wires the bay.
The open lower panel of a grey cabinet with copper busbars, crimped cable lugs and black and orange power cables dropping into a floor trench, a braided earth strap beside them.
Output busbars and cable lugs at the base of a cabinet, cables run down into a floor trench.

Before you ask for a quote

Have these ready before you talk to a supplier. A data sheet for the device under test helps.

  • The device under test: type, rated power, voltage, frequency and number of phases
  • Whether it exports power, and how much
  • The standards and test items you must run
  • Highest and lowest voltage and frequency you need to reach
  • Harmonics or custom waveforms you need to apply
  • Any hardware-in-the-loop work and the real-time simulator you use
  • Your building supply voltage and spare capacity
  • Floor space, cooling and where the cables will run
  • Interfaces and automation software you control it from
  • Other equipment in the bay: DC sources, PV simulators, loads

Grid simulator questions

Information only. These answers are general and do not replace the maker's instructions, the standard itself or advice from a qualified engineer. See the disclaimer.

What is a grid simulator?

A programmable AC power source that stands in for the utility grid during a test. It holds voltage and frequency where you set them and can change them on command, so equipment that connects to the grid can be tested against normal and abnormal conditions in a lab.

Is a grid simulator the same as a grid emulator?

Usually, but the words are not used consistently. Makers sell power-level units under both names. At least one real-time simulation company uses grid simulator for signal-level references and grid emulator for units that exchange real power with the device. When you ask for a quote, describe the power your device draws and exports rather than relying on the name.

What does regenerative mean?

A regenerative grid simulator can take power back from the device under test and feed it to the building supply instead of turning it into heat. One maker states that its units return power at over 90% conversion efficiency.

Do I need a regenerative unit?

If the device exports power, such as a solar or storage inverter or a bidirectional charger, the exported power has to go somewhere. The traditional setup puts a load bank in parallel with the device and the AC source. A regenerative unit absorbs it instead. For devices that only draw power, a non-regenerative source can do the job.

Single-phase or three-phase?

Match the device under test. Some three-phase grid simulators switch to single-phase output and keep their full rating, and some can be set up for split-phase, which helps a lab that tests both residential and commercial products.

How much power do I need?

Start from the rated output of the largest device you will test and add margin. Units of the same rating can often run in parallel; one maker allows four in parallel, and another lists systems up to the megawatt range. Ask about kVA as well as kW, since ride-through tests can call for reactive power.

What is low voltage ride-through testing?

The grid simulator dips the voltage by a set depth for a set time, and the inverter must keep running through it. The required time depends on how deep the dip is, and the inverter may also have to supply reactive power that matches the dip. A programmable sequence lets the simulator follow the curve in the standard step by step.

What is anti-islanding testing?

It checks that an inverter stops exporting when the grid supply is lost. The test bench includes an AC source and AC loads, often a tuned resistive, inductive and capacitive load, and the grid side is disconnected to see how quickly the inverter detects the island and shuts down. IEC 62116 sets this procedure for PV inverters.

What is power hardware-in-the-loop?

A real-time simulator runs a model of the grid, and the grid simulator reproduces that modeled voltage at the terminals of real hardware at full power. The hardware's response feeds back into the model. The grid simulator needs an analog input and a short delay from signal to output; one maker quotes under 100 microseconds.

Which standards is a grid simulator used for?

Common ones are IEEE 1547 and its test procedures in IEEE 1547.1, UL 1741 with Supplement SB, IEC 62116 for anti-islanding, and the IEC 61000-4 immunity tests such as 61000-4-11 for voltage dips. Bidirectional EV chargers are covered by UL 9741. Which apply depends on your product and market.

Can it test appliances and power supplies too?

Yes. A grid simulator is a constant-voltage AC source, so it can supply appliances, industrial power supplies and chargers while it applies dips, interruptions, voltage variations and harmonics for immunity tests.

Does it need an isolation transformer?

It depends on the unit. One maker builds isolation into the input side so no separate isolation device is needed on the device side. Ask your supplier how its output is isolated and what your test setup needs.